Skip Navigation Links
 Registration 
 Pre Registered 
 Abstracts 
  Scientific Program 
 Exhibition 
 Contact Us 
 Personal page 
Scroll up
Scroll down
                                           اولین ويژه نامه همايش بهاره چشم پزشكي منتشر شد       شب بهاری چشم پزشکی با گروه موسیقی رستاک       جشنواره فیلم        هفتمین همایش سالیانه IRAVO       اولین همایش بهاره چشم پزشکی
Skip Navigation Links
        ساختار همایش
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه همایش
        جشنواره فیلم
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
 
مقاله Abstract


Title: Comparative analysis of the visual performance after implantation of the Toric Implantable Collamer Lens in stable keratoconus: 4-year follow-up
Author(s): Farideh Doroodgar1, Azad Sanginabadi, Feazollah Niazi2, Alireza Baradaran-Rafie
Presentation Type: Oral
Subject: Cornea and Refractive
Others:
Presenting Author:
Name: Farideh Doroodgar
Affiliation :(optional) Negah eye hospital
E mail: farinaz_144@yahoo.com
Phone: 09125259912
Mobile: 09125259912
Purpose:

To report on 4-year postoperative visual performance with the Toric Implantable Collamer Lens (TICL) for stable keratoconus

Methods:

Forty eyes of 24 patients with stable keratoconus with myopia between 0.00 and -18.00 diopters (D) and astigmatism between 1.25 and 8.00 diopters were evaluated in this prospective interventional study (https://clinicaltrials.gov/ct2/show/NCT02833649). We evaluated refraction, Visual outcomes, astigmatic changes analyzed by Alpins vector, contrast sensitivity, aberrometry, Modulation transfer functions (MTF), defocus curve, subjective satisfaction, and operative and postoperative complications

Results:

At 4-year follow-up, 45% had 20/20 vision or better and 100% had 20/40 or better uncorrected visual acuity (UCVA). Vector analysis of refractive astigmatism shows that, the SIA (3.20±1.46D) wasn’t significantly different from the TIA (3.14±1.42 D) (p= 0.620). At 4 years postoperatively, none of the eyes showed a decreased in UCVA, in contrast to 24 eyes in which UCVA was increased by ≥1 lines, with contrast sensitivity and improvement in total aberrations and MTF value at 5 per degree (p*꞊0.004 ) after TICL implantation. The cumulative 4-year corneal endothelial cell loss was ≤5%. No patients reported dissatisfaction, and 100% of patients reported they would choose implantable collamer lens (ICL) implantation again. At the end of follow-up, the vault was 658±54.33µm (range, 500-711) and the intraocular pressure (IOP) was 11.7±2.08 mmHg. Occurrences of glare and night-driving troubles diminished after TICL surgery

Conclusion:

The results from this standardized clinical investigation support TICL implantation from clinical and optical viewpoints in patients with stable keratoconus

Attachment:





Last News

  - اولین ويژه نامه همايش بهاره چشم پزشكي منتشر شد
  - شب بهاری چشم پزشکی با گروه موسیقی رستاک
  - جشنواره فیلم
  -  هفتمین همایش سالیانه IRAVO
  - اولین همایش بهاره چشم پزشکی